Viessmann · Heat pump

GAS A2L gas leak

Critical severity Vitocal 100-WA

What the control is telling you

A2L refrigerant leak detected. The compressor is off and the blower runs continuously.

Applies to: Vitocal 100-WA display

Likely causes

  • A2L refrigerant leak

Test and repair steps

  1. Verify the leak mitigation conditions at the control board, compressor and blower.
  2. Find and repair the leak following the refrigerant service procedure.
  3. Cycle power to clear the alarm.

Models that show this code

5 models in Vitocal 100-WA

AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056

Other codes on the same units

  • CON Condensate level too high
  • FrE Freeze protection active
  • HI Compressor high speed
  • HOP High over pressure
  • LO Compressor low speed
  • LUP Low under pressure
  • NSU Not set up
  • Power LED Power indicator light

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 48. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.