E91 Compressor weak magnetic protection alarm

Medium severity Vitocal 100-AW AM2V

What the control is telling you

Alarm from weak magnetic protection of the compressor. The outdoor unit is not running.

Applies to: Outdoor unit

Likely causes

  • Outdoor unit not running

Test and repair steps

  1. Check the refrigeration system.
  2. If it is OK, replace the compressor driver board.

Other codes on the same units

  • E81 - E82 Reserved
  • E83 15 VDC under voltage
  • E84 - E89 Reserved
  • E90 Compressor frequency not being maintained
  • E92 Power unit overheating alarm
  • E93 Reserved
  • E94 AC input current down alarm
  • E95 EEPROM failure warning

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 84. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.