EH 60 Indoor room temperature sensor T1 open or shorted

Medium severity Vitocal IND-O

What the control is telling you

Operation lamp flashes 6 times, timer lamp off. Sensor T1 is open circuit or shorted. With only one faulty temperature sensor the unit keeps running and shows the code for emergency use. With more than one faulty sensor the unit stops.

Applies to: DLFSOAH09XAK, DLFSOAH18XAK indoor units

Likely causes

  • Sensor T1 open circuit
  • Sensor T1 short circuit

Other codes on the same units

  • EH 0b Communication error between display board and main board
  • EH 31 Upper indoor fan speed outside normal range
  • EH 32 Lower indoor fan speed outside normal range
  • EH 3A External fan DC bus voltage too low
  • EH 3b External fan DC bus voltage too high
  • EH 61 Evaporator coil temperature sensor T2 open or shorted
  • EH b3 Communication error between wired controller and indoor unit
  • EH bA Communication fault between external fan module and indoor unit

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: DLFSOAH service manual, PDF p. 8, 15. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.