Water heater troubleshooting guides
117 guides. Troubleshooting guides for water heater equipment. Each one lists the likely causes and what to check, in order.
Navien (98)
- Air filter cleaning
Clean the air filter on top of the unit at least once a year or whenever the air filter alarm shows on the front panel. - Annual maintenance of the water heater in a DHW/heating system
Water heaters used for DHW and heating should be maintained and flushed once a year. - Annual routine maintenance checklist
Basic yearly tasks to keep the unit efficient and safe. - Annual T&P relief valve maintenance
The T&P valve must be fitted and operated at least once a year so it does not stick. Water is extremely hot when discharged. - Anti-legionella cycle safety
When anti-legionella is enabled, the tank heats to 140°F (60°C) at the set interval (default 7 days, adjustable 1 to 30 days). A mixing valve must be - Anti-seize valve and EEV movement
The shut-off valve and electronic expansion valve move for a set period at regular intervals to prevent seizing. No technician action is needed. - Before first power-up: fill and purge the tank
The unit has a dry fire check that only runs at the first power connection. Do not rely on it to protect the heating elements. - Check compatibility before installing the HotButton Kit
The kit only works with A-type NPE-A (180A/210A/240A) or NPN/NHW700 water heaters. It does not work with S-type NPE units, with cascade (multi-unit) i - Choosing an operating mode
Energy Saver (default) combines heat pump and electric heater. High Demand uses the electric heater more often for faster recovery. Heat Pump uses onl - Choosing the installation location
Pick an indoor spot near where the cold water supply enters the building. Keep the air filter and condensate drain easy to reach. Do not install it wh - Clean the air filter
Clean at least yearly or when the air filter alarm shows, even if it does not look clogged. - Cleaning the water heater exterior
Clean only the outside of the unit. The front panel is moisture resistant but not waterproof. - Clogged condensate drain
The internal condensate system needs no routine service unless a fault or overflow occurs. The compressor stops automatically when leakage or overflow - Condensate drain clogged or overflow
Condensate system needs no routine care. Compressor stops automatically when leakage or overflow is detected. - Condensate system
The internal condensate system needs no routine maintenance unless a fault code or overflow occurs. The condensate drain inspection section (6.3) is o - Connecting a CTA-2045 demand response module
A CTA-2045 module (not supplied) connects to the designated port in the junction box on the top right side. Follow the supplier's instructions for sta - Connecting the H2Air main control connector
The H2Air links to the Navien water heater through a 13-pin main control cable. - Connecting the hot and cold water supply lines
Pipe the water heater to the home's supply using the ¾ inch NPT fittings. Connect either the top or the side fittings, never both. Unions make later r - Connecting the power supply wires
Power the heater only after the tank is full and purged, and after the wiring is complete. Work only on a de-energized circuit, and only licensed prof - Connecting the T&P relief valve discharge pipe
The T&P relief valve is factory installed. Its discharge pipe must be sized, sloped and routed so pressure can always be relieved. Never reuse an old - Delayed hot water at fixture with recirculation mode on
Hot water takes too long to reach the fixture when recirculation is enabled. - Delayed hot water at fixture with recirculation on
Hot water arrives late at the fixture when recirculation is enabled. - Deleting a weekly recirculation schedule
Remove a saved weekly schedule entry. - Deleting or viewing weekly hot water schedules
Weekly schedules are viewed and deleted from the Schedule menu's Weekly List. The selected days show at the bottom of the screen. - Deleting recirculation weekly schedules
Recirculation schedules are viewed and deleted from the Weekly Menu. - Demand response (CTA-2045-B) requirements
Demand response is disabled by default. When enabled with a CTA-2045 or EcoPort module, the unit responds to utility commands such as Shed or Load Up. - Diagnostic checks in Installer Menu (partial list)
The listed diagnostic items are Leak Detection System Check, which operates the shut-off valve fully open or closed and checks the rate, and Heat Pump - Drain and flush the storage tank
Yearly flush to remove mineral deposits and reduce odors. - Drain and flush the tank
Do this at least once a year to remove mineral deposits and reduce odor. - Draining the water heater
Drain before maintenance such as cleaning the inlet water filter, or before a long shutdown to prevent freezing. - Earthquake and seismic bracing
In earthquake-prone areas, secure the unit with straps per local building code. California requires bracing, anchoring, or strapping for all water hea - External pump installation guidelines
General guidelines for an external circulator pump on H2Air systems. - External recirculation system layout
An external loop lets hot water circulate continuously or on demand, which cuts the wait for hot water at fixtures. It usually uses a dedicated return - Fallback to alternate heat source
If the selected heat source cannot run, the tank keeps heating with the other source until the original one returns to normal. - Freeze protection (display shows Freeze Protection in Progress)
When tank water drops below the freeze protection setting (default 43°F / 6°C), the electric heater turns on to warm the tank. It stops once the water - Freeze protection of water lines
If the area can reach 32°F (0°C) or lower, the pipes can freeze. Insulate them and consider heat tape. - Freeze risk during power outages and long shutdowns
During a power failure in cold weather, the freeze protection does not run and the heat exchanger can freeze. Where outages are common, drain the heat - Front panel flashing red with error icon (level 1 error)
A level 1 error is active. Operation continues during a level 1 error. - Front panel shows Freeze Protection in Progress
When tank water falls below the freeze threshold, the electric heater turns on to warm the tank. It stops once the tank reaches a set level. This is n - Getting service for a water heater
Repairs on this water heater need pre-authorization from Navien Technical Support before work starts. Have the installer or a licensed professional ma - Ground wiring with metal conduit
Conduit can be used as the ground path if it meets the limits below. For full grounding detail, follow the current NFPA-70 edition. - Heat pump operation prevention (display shows Operation Prevention in Progress)
The heat pump only runs when the ambient air is between 41°F (5°C) and 113°F (45°C) and the tank water is between 50°F (10°C) and 149°F (65°C). Outsid - Hot water at the tap is not hot enough
Water at the fixture is lukewarm, even with the water heater set normally. - Hot water at the tap is too hot
Water from the hot tap is hotter than wanted. - Hot water still not hot enough at a high temperature setting
Water stays lukewarm even when the water heater is set high. - Install the H2Air controller in a water heater
Mounting the H2Air add-on controller inside the water heater. The mounting method depends on the model (NPE-A, NPE-A2/S2, NHW700-A or NPN). - Install the HotButton Kit on a non-pump model
Mounting on the panel bracket for the non-pump NPN/NHW700. Power must be off before starting. - Install the HotButton Kit on a pump model
Pump model mounting on the front panel support bracket. The manual's step order is not clearly tied to the model, so check against the unit in hand. - Install the temperature sensor (optional)
The sensor is optional on the non-pump model. Remove the default metal plate from SENSOR I before connecting a sensor. - Installer Menu functions
Installer Menu holds the Service Wizard, Parameter Settings, Factory Reset and password change. Factory Reset resets all parameters on the panel and c - Installing a thermostatic mixing valve
Scald risk exists even at low set temperatures, so a mixing valve is needed at each point of use. On solar-fed systems (not recommended), limit inlet - Installing a wired HotButton
Wire the temperature sensor and wired push button to the recirculation pump. - Installing the drain pan
A drain pan is required under the heater to catch leaks, where local code requires it. Without one, leaks can damage nearby walls, floors and ceilings - Installing the leak detection system (optional accessory)
Sensor detects water in its location and alerts through an error code on the front panel, flashing light and audible signal. Alert can also be seen in - Installing the shut-off valve (optional accessory)
Optional valve that closes automatically when a leak is detected. Connector goes to the SHUT OFF connector inside the controller cover. - Installing the shut-off valve (optional, side mount)
Side installation of the optional shut-off valve used with the leak detection system. - Installing the shut-off valve (optional, top mount)
The optional shut-off valve stops the water supply when the leak detection system senses a leak. It is not installed by default. Mount it on the top n - Leak detection system (optional) alert behavior
The leak detection sensor alerts on a leak. The front panel shows an error code with a flashing light and an audible signal. The alert can also be che - Leak protection and drain pan
Tank and pipe leaks can cause water damage and fire risk. Protect the area with a drain pan, a leak detector with automatic shutoff, and the Navien le - Level the unit and set vertical installation
The unit must sit vertically on a level surface. Tilting more than the limit can block drainage and cause internal damage. - Limiting high incoming water pressure
Pressure above the recommended range can damage the tank and cause early leaks. Some homes run above 100 psi. - Louver and undercut door sizing for enclosures
Louvers and undercut doors must give enough free area for air to move. Louver position matters. - Low water pressure
Water pressure at the outlets is low. - Not enough or no hot water
The heater is not supplying enough hot water, or none at all. - Not enough or no hot water: demand and power
Low hot water can come from heavy use, a blown fuse or tripped breaker, power off, or a low temperature setting. - Not enough or no hot water: faucets, wiring, ECO, vacation
Other causes of low hot water. - Prepare unit for extended inactivity
Steps to take when the unit will sit unused for a long time. - Recirculation piping with NaviCirc, side inlet and outlet
Piping layout when the NaviCirc recirculation pump is used with side inlet and outlet connections. The return line can go to the top inlet. - Recirculation piping with NaviCirc, top inlet and outlet
Piping layout when the NaviCirc recirculation pump is used with top-mounted inlet and outlet connections. The return line can go to the optional side - Relief valve popping or discharging
Thermal expansion in a closed system raises pressure. This is not acceptable and must be corrected. - Relief valve popping or draining
Pressure is building up from thermal expansion in a closed water system. This is not an acceptable condition and must be corrected. - Replace blown front panel fuse
The fuse is on the back of the front panel. - Replace front panel battery
The battery is factory-protected by a film. It is recommended to replace it every five years. - Replace pipe O-rings
Use the matching O-ring from the Emergency Parts Kit. Improper or damaged O-rings cause leaks. - Replace the energy cut off (ECO) switch
High-voltage work. Power must be off, and covers must be closed afterward. - Replace the heating element
High-voltage work. Power must be off, and the tank must be full before restart. - Returning a unit to service after long inactivity
Steps to take when the unit will be idle for a long time and before it is restarted. - Routing and pitching the condensate drain
The condensate line must flow freely to an adequate drain. Excessive run length or bends restrict flow. - Rumbling noise
Scale or mineral deposits have built up in the tank. - Rumbling noise from the tank
Scale or mineral deposits building up in the tank cause the noise. - Service Wizard self-check
The Service Wizard runs a self-check on three items: fill water check with dry fire protection, heating element check, and evaporator fan check. - Set a weekly operation schedule
Schedules define operating mode and temperature for chosen days and times. Weekly Enable must be On for the schedule to run. - Side installation of the recirculation pump kit
Connects the recirculation pump through the lower heating element cover. Power must be off before starting. - Suspected gas leak
Smell around the appliance, especially near the floor, before operating. Gas is heavier than air and settles low. - T&P valve drains no water when opened
Annual T&P valve check did not release any water. - T&P valve leaking
Water leaks from the T&P relief valve. The manual gives these corrective measures. - Test and maintain the T&P relief valve
Yearly test to keep the valve from sticking. The unit must always have a working T&P valve. - Thermal expansion tank
Plumbing code requires a correctly sized and pressurized thermal expansion tank when backflow preventers, check valves, or pressure reducing valves ar - Top installation of the recirculation pump
Mounting the recirculation pump on the top of the water heater, including routing the communication cable through the top plate and removing the RE-PU - Top installation of the recirculation pump kit
Connects the ComfortCirc recirculation pump to the water heater's RE-PUMP cable through the front panel. Steps 1 to 5 are on pages 14 and 15, which ar - Venting a closet or small enclosure
Enclosures under 640 ft³ need air exchange so the heat pump does not chill the room and lose efficiency. Acceptable options depend on the enclosure si - Viewing error history
The error history lists the 10 most recent errors, newest at the top. Select an error to see details. The error code table is in section 7.2, which is - Viewing the weekly recirculation schedule list
Check the saved weekly on and off times and days. - Water heater has been under water
Safety-critical. Do not run the unit if any part has been submerged. - Water is too hot
Water at the tap is hotter than expected. - Water odor
The tap water smells bad. - Wire push button switches to the HotButton controller
Wired push buttons need no power source. Several switches can go in parallel on the same terminals, or on a common branch circuit. - Wire the 13-pin main control connector
Connects the kit to the water heater PCB. The NPN/NHW700 cable is 400 mm long.
Viessmann (19)
- Choosing between instantaneous DHW (B1KE) and a storage tank (B1HE)
The B1KE suits single or multiple draw points and tight spaces. The B1HE suits high simultaneous demand and existing tank systems. - Cleaning the inside of the DHW tank
Cleaning the interior requires draining the tank and reassembling it with a new gasket. The water being drained may be hot. - DHW connection layout and relief valve installation
Layout drawing for DHW piping. Piping must be field verified by the heating contractor. Key points: install the relief valve on each tank per code, fi - DHW tank maintenance
DHW tank and connections need periodic checks. Water treatment equipment must be refilled in time. - DHW tank safety valve check
The safety valve should be checked by venting. The valve seat can become contaminated. - Domestic water connections
Piping between boiler and tank with service-accessible connections and the required safety devices. Drawing is conceptual only; field piping must be v - Fit the cosmetic covers
Covers go on after the insulation is in place. Auxiliary port parts apply only to 66 and 79 USG models. - Heating system connections for solar with extra tank
Recommended piping for a solar application with an additional tank. The DHW temperature must be limited to 140°F (60°C) with an anti-scald tempering v - Install the BSPT to NPT adaptors on the potable water connections
Three 1 in. BSPT to 1 in. NPT adaptors go on the potable water connections. Check the position against the fitting diagrams for your tank size. - Install the DHW tank temperature sensor
Sensor is mounted in the tank sensor well using the supplied mounting hardware. - Install the G to NPT adaptors on the heating water connections
Two 1 in. G to 1 in. NPT adaptors go on the heating system supply and return. Each one uses the gasket supplied with it. - Install the impressed current anode
Field-installed anode with its electronic unit mounted on the tank jacketing. Power is connected only after the tank is filled. - Level the DHW tank
Level the tank with the adjustable feet. - Mount the impressed current anode electronic unit
The impressed current anode is supplied with the tank but is installed in the field. Isolate the power before working on it. - Move the DHW tank with the carrying handles
Use the integrated handles to move the tank. Two people are needed. The tank has two handles in the base and two at the top under the top panel. - Potable water filter service
Filter service intervals depend on the filter type to keep hygiene. - Remove the hydronic connection protective covers
Each threaded connection has a protective cover that must be removed before fitting adaptors. - Temperature and pressure relief (T&P) valve checks
The T&P valve must stay unobstructed and visible for discharge. Water leaking or discharging from it means unsafe temperature or pressure build-up is - Temperature and pressure relief valve discharge line
The T&P valve is supplied with the tank and must be installed to code. The discharge line must be safe for attendants and must not restrict flow.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.