Viessmann · Water heater troubleshooting
Fit the cosmetic covers
What is going on
Covers go on after the insulation is in place. Auxiliary port parts apply only to 66 and 79 USG models.
Check in this order
- Place the insulation mat over the top port, then the top cover, with the cable relief cutout aligned to the anode cable.
- On 66 and 79 USG models only, apply pipe thread sealant to the supplied plug and install it in the auxiliary port.
- Trim the insulation mat for the inspection port, place it, and install the screws for the inspection port cover.
- On 66 and 79 USG models only, install the screws for the auxiliary port cover.
- On 66 and 79 USG models only, slide the auxiliary cover down over the screws and push it into place.
- Slide the inspection port cover down over its screws.
Applies to: Vitocell 100-V CVWC all sizes
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocell 100-V CVWC installation, service and operating instructions, p. 20. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.