Viessmann · Water heater troubleshooting

DHW connection layout and relief valve installation

Vitocell 100-V

What is going on

Layout drawing for DHW piping. Piping must be field verified by the heating contractor. Key points: install the relief valve on each tank per code, fit shut-off valves, and use a precharged expansion tank wherever a backflow preventer is installed.

Check in this order

  1. Install the T&P relief valve on each tank in a way that meets local code.
  2. Fit shut-off valves on the DHW supply and cold water lines.
  3. Run a discharge pipe from the relief valve and a drain.
  4. Where a backflow preventer is installed, add a precharged expansion tank per local plumbing code.
  5. Fit a thermostatic mixing or anti-scald valve on the DHW outlet.
  6. Field verify the full piping arrangement, since the drawing is conceptual.

Applies to: Vitocell 100-V CVWC

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocell 100-V CVWC Technical Data Manual, p. 17. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.