Viessmann · Water heater troubleshooting

Domestic water connections

Vitocell 100-V

What is going on

Piping between boiler and tank with service-accessible connections and the required safety devices. Drawing is conceptual only; field piping must be verified by the heating contractor.

Check in this order

  1. Use detachable fittings for all pipe work.
  2. Pipe the boiler and tank together, using the factory supplied adaptors so connections are accessible for service.
  3. Seal unused connections with brass caps.
  4. Insulate the domestic hot water supply piping.
  5. Fit a recirculation pump, check valve and time switch on the DHW recirculation pipe, if used.
  6. Install the required isolation valves, drain valve, pressure reducing valve, water filter, backflow preventer and expansion tank where local code requires them.
  7. Install a field-supplied anti-scald tempering valve where DHW temperature may exceed local limits or 140°F (60°C).

Applies to: Vitocell 100-V CVWC domestic hot water piping

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocell 100-V CVWC installation, service and operating instructions, p. 22-23. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.