Viessmann · Water heater troubleshooting

Install the BSPT to NPT adaptors on the potable water connections

Vitocell 100-V CVWC

What is going on

Three 1 in. BSPT to 1 in. NPT adaptors go on the potable water connections. Check the position against the fitting diagrams for your tank size.

Check in this order

  1. Apply thread sealer to the tank connections before installing the adaptors.
  2. Thread the 1 in. BSPT to 1 in. NPT adaptor into the potable water connection. Do not overtighten, because this can damage the glass lining and void the warranty.
  3. Use the two-hand wrench method. Hold the adaptor with one wrench to stop it twisting, and tighten the fitting or pipe with the second wrench.
  4. Repeat for the remaining adaptors.

Applies to: All Vitocell 100-V CVWC sizes

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocell 100-V CVWC installation manual, p. 15. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.