Navien · Water heater troubleshooting
Connecting the hot and cold water supply lines
What is going on
Pipe the water heater to the home's supply using the ¾ inch NPT fittings. Connect either the top or the side fittings, never both. Unions make later removal easier. Dielectric unions help stop corrosion from the small currents in copper pipe.
Check in this order
- Confirm the home's pipe type and use potable-approved pipe and sealant.
- Connect the cold supply to the cold connection using ¾ inch NPT.
- Connect the hot outlet to the hot connection using ¾ inch NPT.
- Check that hot and cold lines are on the correct fittings.
- Plug and cap all unused hot and cold connections.
- If needed, install a pressure reducing valve set to 50-60 psi and a thermal expansion tank.
- Fill the tank, then open each hot faucet slowly to vent air from the heater and piping.
- Do not overtighten, to avoid damaging the gaskets.
- Do not solder pipe while it is attached to the heater. Solder a short pipe to a threaded adapter first, using 95/5 tin-antimony solder or equivalent, and keep wet rags on the heater connections.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 24. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.