Anti-legionella cycle safety
What is going on
When anti-legionella is enabled, the tank heats to 140°F (60°C) at the set interval (default 7 days, adjustable 1 to 30 days). A mixing valve must be installed to prevent scalding.
Check in this order
- Confirm a mixing valve is installed before enabling anti-legionella.
- Set the Anti-Legionella Cycle interval if the 7-day default is not wanted.
Applies to: NWP500 series
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 62. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.