Navien · Water heater troubleshooting

Before first power-up: fill and purge the tank

NWP500

What is going on

The unit has a dry fire check that only runs at the first power connection. Do not rely on it to protect the heating elements.

Likely causes

  • Tank not full of water when power is applied.
  • Air still trapped in the tank.
  • Unit transported horizontally and powered too soon.

Check in this order

  1. Confirm the tank is completely filled with water.
  2. Confirm all air has been purged from the tank.
  3. If the unit was moved horizontally, stand it upright and wait at least 24 hours before powering on.
  4. Apply power only after the tank is full and purged.

Applies to: NWP500-50, NWP500-65, NWP500-80

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 User's Information Manual, p. 12. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.