Navien · Water heater troubleshooting
Annual T&P relief valve maintenance
What is going on
The T&P valve must be fitted and operated at least once a year so it does not stick. Water is extremely hot when discharged.
Check in this order
- Make sure no one is nearby before opening the valve.
- Open the T&P valve handle on the side of the water heater and drain 1–2 gallons.
- If no water comes out, turn the water heater off and contact a licensed professional or Navien Technical Support.
- Do not block the T&P valve discharge outlet.
- If the T&P valve leaks, install a PRV on the cold inlet (recommended 50–60 psi), add an expansion tank with the correct pressure, and adjust the temperature setting if needed.
Applies to: NWP500 series
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 64. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.