Navien · Water heater troubleshooting

Connecting the power supply wires

NWP500

What is going on

Power the heater only after the tank is full and purged, and after the wiring is complete. Work only on a de-energized circuit, and only licensed professionals should make these connections.

Check in this order

  1. Turn the breaker or fuse for the heater OFF.
  2. Confirm the circuit is dead with a non-contact tester.
  3. Check the rating plate and confirm the supply matches it.
  4. Loosen the two screws and remove the junction box cover from the power/CTA module.
  5. Connect the ground wire to the green ground screw.
  6. Connect the home's two power wires to the heater's two harness wires.
  7. Reinstall the junction box cover and secure it with the two screws.
  8. If any part was submerged in water, take the heater out of service and have qualified personnel replace it.

Applies to: NWP500-50, NWP500-65, NWP500-80

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 28-29. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.