What is going on
Power the heater only after the tank is full and purged, and after the wiring is complete. Work only on a de-energized circuit, and only licensed professionals should make these connections.
Check in this order
- Turn the breaker or fuse for the heater OFF.
- Confirm the circuit is dead with a non-contact tester.
- Check the rating plate and confirm the supply matches it.
- Loosen the two screws and remove the junction box cover from the power/CTA module.
- Connect the ground wire to the green ground screw.
- Connect the home's two power wires to the heater's two harness wires.
- Reinstall the junction box cover and secure it with the two screws.
- If any part was submerged in water, take the heater out of service and have qualified personnel replace it.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 28-29. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.