Louver and undercut door sizing for enclosures
What is going on
Louvers and undercut doors must give enough free area for air to move. Louver position matters.
Check in this order
- Size any louver to provide at least 130 in² of free area.
- Make an undercut door gap at least 0.75 in, giving at least 18 in² of air passage.
- Place a louver near the top of the water heater.
- Keep to the minimum space rules. Undersized spaces reduce efficiency and slow recovery.
Applies to: NWP500 series, enclosed installations
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 21. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.