Navien · Water heater troubleshooting
Front panel shows Freeze Protection in Progress
What is going on
When tank water falls below the freeze threshold, the electric heater turns on to warm the tank. It stops once the tank reaches a set level. This is normal protection.
Likely causes
- Tank water temperature is below the freeze threshold (default 43°F / 6°C).
Check in this order
- Keep the unit powered so the electric heater can run.
- Wait until the tank warms and the message clears.
Applies to: NWP500 series
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 User's Information Manual, p. 25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.