What is going on

Scald risk exists even at low set temperatures, so a mixing valve is needed at each point of use. On solar-fed systems (not recommended), limit inlet temperature with a mixing valve. Solar water can exceed 170°F (77°C).

Likely causes

  • Solar hot water supply above 170°F (77°C).

Check in this order

  1. Install a thermostatic mixing valve at each point of use.
  2. For a solar-fed system, install a mixing valve in the supply line to limit inlet water to 120°F (49°C).

Applies to: NWP500-50, NWP500-65, NWP500-80

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 31. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.