Navien · Water heater troubleshooting

Not enough or no hot water: demand and power

NWP500

What is going on

Low hot water can come from heavy use, a blown fuse or tripped breaker, power off, or a low temperature setting.

Likely causes

  • Water use exceeded the tank capacity
  • Blown fuse or tripped breaker
  • Electric supply turned off
  • Temperature setting too low

Check in this order

  1. Wait for the unit to recover after heavy demand.
  2. Replace the fuse or reset the breaker.
  3. Confirm the power supply is connected (section 3.6).
  4. Check the temperature setting (section 5.3).

Applies to: NWP500-50, NWP500-65, NWP500-80

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 71. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.