Navien · Water heater troubleshooting
Install the HotButton Kit on a non-pump model
What is going on
Mounting on the panel bracket for the non-pump NPN/NHW700. Power must be off before starting.
Check in this order
- Turn off power to the water heater and disconnect the supply.
- Remove the two upper screws from the front cover with a Phillips screwdriver. Release the toggle latch at the bottom of the front cover.
- Remove the three screws holding the panel bracket and take the bracket off.
- Remove the two screws holding the PCB box and take the PCB box out of the system.
- Install the HotButton Kit on the back of the panel bracket. Line up the three latches with the mounting location, then slide the kit downward to lock it.
- Connect the cables to the HotButton Kit as described in the wiring section.
- Put the PCB box back and secure it with the two screws.
- Put the panel bracket back and secure it with the three screws.
- Close the front cover, secure the two upper screws, and lock the toggle latch.
- Label all cables before disconnecting anything inside the unit. Verify wiring and unit operation after service.
Applies to: NPN/NHW700 non-pump model
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien HotButton add-on controller installation manual, p. 1–2. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.