What is going on
The T&P valve must stay unobstructed and visible for discharge. Water leaking or discharging from it means unsafe temperature or pressure build-up is possible. Mineral build-up on the valve seat is possible.
Likely causes
- Mineral build-up on the T&P valve seat
- Unsafe temperature or pressure build-up in the tank
Check in this order
- Make sure there is no valve or restriction between the tank and the T&P valve, or between the T&P valve and the discharge outlet.
- Check that the discharge line slopes to allow unobstructed, visible flow toward a floor drain.
- If water is coming out of the discharge pipe, contact the heating contractor immediately.
- Operate the valve test lever at least once per year to confirm the waterways are clear.
- Have a licensed professional heating contractor reinspect the T&P valve at least once every three years.
- Report any dripping or discharge from the T&P valve to the heating contractor right away.
Applies to: Vitocell 100-V CVWC
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, p. 27. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.