Viessmann · Water heater troubleshooting

Temperature and pressure relief (T&P) valve checks

Vitocell 100-V CVWC

What is going on

The T&P valve must stay unobstructed and visible for discharge. Water leaking or discharging from it means unsafe temperature or pressure build-up is possible. Mineral build-up on the valve seat is possible.

Likely causes

  • Mineral build-up on the T&P valve seat
  • Unsafe temperature or pressure build-up in the tank

Check in this order

  1. Make sure there is no valve or restriction between the tank and the T&P valve, or between the T&P valve and the discharge outlet.
  2. Check that the discharge line slopes to allow unobstructed, visible flow toward a floor drain.
  3. If water is coming out of the discharge pipe, contact the heating contractor immediately.
  4. Operate the valve test lever at least once per year to confirm the waterways are clear.
  5. Have a licensed professional heating contractor reinspect the T&P valve at least once every three years.
  6. Report any dripping or discharge from the T&P valve to the heating contractor right away.

Applies to: Vitocell 100-V CVWC

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, p. 27. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.