Navien · Water heater troubleshooting
Not enough or no hot water
What is going on
The heater is not supplying enough hot water, or none at all.
Likely causes
- Water use exceeded the tank capacity
- Blown fuse or tripped breaker
- Electric supply turned off
- Thermostat set too low
- Open or leaking hot water faucets
- Interruption of the home's electric service
- Improper wiring or sensor failure
- Manual reset limit (ECO) has tripped
- Vacation Mode is active
- Cold inlet water in winter takes longer to heat
- Not enough air exchange for heat pump operation (air temperature drops more than 15°F / 8°C during heat pump operation)
Check in this order
- Wait for the heater to recover after an unusually high demand.
- Replace the fuse or reset the circuit breaker.
- Confirm the electric supply to the heater is connected properly. Refer to Connecting the Power Supply in the Installation Manual.
- Check the temperature setting and raise it if needed. Refer to section 3.3 on page 13.
- Close all faucets and check for plumbing leaks.
- Contact the local electric utility if service was interrupted.
- Confirm the power supply wires are connected properly. Refer to Connecting the Power Supply Wires in the Installation Manual.
- Check the temperature regulation of the heater and refer to Important Safety Information on page 5 for the manual reset (ECO).
- Disable Vacation Mode. Refer to section 3.5 on page 15.
- Add more air circulation around the heater if the air temperature drops more than 15°F (8°C) during heat pump operation.
Applies to: NWP500 series
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 user information manual, p. 33. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.