Navien · Water heater troubleshooting

Clogged condensate drain

NWP500

What is going on

The internal condensate system needs no routine service unless a fault or overflow occurs. The compressor stops automatically when leakage or overflow is detected.

Likely causes

  • Sediment or algae in the condensate drain pan or hose

Check in this order

  1. Turn off power to the water heater.
  2. Remove the condensate drain and open the cleaning port.
  3. Clear debris with a brush or pipe cleaner through the port.
  4. Use a wet/dry vacuum or diluted bleach if needed to remove what is left.
  5. Reinstall the cleaning port and restore power.

Applies to: NWP500-50, NWP500-65, NWP500-80

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 65. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.