Replace the energy cut off (ECO) switch
What is going on
High-voltage work. Power must be off, and covers must be closed afterward.
Check in this order
- Turn off power to the water heater.
- Remove the 2 screws from the upper and lower heating element covers and take the covers off.
- Pull the safety cover forward to remove it.
- Remove the 4 screws on the ECO wires and the 2 bolts on the ECO bracket. Disconnect the wires from the ECO switch.
- Separate the ECO switch from the ECO bracket.
- Install the new switch, connect the 4 ECO wires with 4 screws, and reinstall the safety cover and element cover.
- Restore power and confirm normal operation.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 67-68. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.