Navien · Water heater troubleshooting
Install the HotButton Kit on a pump model
What is going on
Pump model mounting on the front panel support bracket. The manual's step order is not clearly tied to the model, so check against the unit in hand.
Check in this order
- Turn off power and disconnect the supply before opening the unit.
- Remove the two upper front cover screws and release the toggle latch.
- Remove the two screws holding the PCB box and take the PCB box out.
- Install the HotButton Kit on the water heater bracket. Line up the latch on the kit case with the mounting location on the front panel support bracket. Insert the latch into the mounting hole and slide the kit to secure it.
- Once the plumbing is fully installed, set the 2-way valve to the EXTERNAL position.
- Connect the cables to the HotButton Kit as described in the wiring section.
- Replace the PCB box and secure it with the two screws.
- Close the front cover, secure the two upper screws, and lock the toggle latch.
Applies to: NPN/NHW700 pump model
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien HotButton add-on controller installation manual, p. 2. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.