Navien · Water heater troubleshooting

Demand response (CTA-2045-B) requirements

NWP500

What is going on

Demand response is disabled by default. When enabled with a CTA-2045 or EcoPort module, the unit responds to utility commands such as Shed or Load Up. A thermostatic mixing valve certified to ASSE 1017 is required on the hot water outlet.

Check in this order

  1. Install an ASSE 1017 certified thermostatic mixing valve on the hot water outlet pipe.
  2. Follow the mixing valve maker's installation instructions.
  3. Enable the DR function in the front panel settings menu only if the module is connected.
  4. If normal operation is needed, disable DR; the unit returns to normal mode for up to 72 hours.

Applies to: NWP500 series with CTA-2045 or EcoPort module

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 63. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.