Demand response (CTA-2045-B) requirements
What is going on
Demand response is disabled by default. When enabled with a CTA-2045 or EcoPort module, the unit responds to utility commands such as Shed or Load Up. A thermostatic mixing valve certified to ASSE 1017 is required on the hot water outlet.
Check in this order
- Install an ASSE 1017 certified thermostatic mixing valve on the hot water outlet pipe.
- Follow the mixing valve maker's installation instructions.
- Enable the DR function in the front panel settings menu only if the module is connected.
- If normal operation is needed, disable DR; the unit returns to normal mode for up to 72 hours.
Applies to: NWP500 series with CTA-2045 or EcoPort module
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 63. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.