Installing the shut-off valve (optional, side mount)
What is going on
Side installation of the optional shut-off valve used with the leak detection system.
Check in this order
- Turn the heater power OFF.
- Mount the shut-off valve on the side of the unit.
- Remove the two screws from the lower heating element cover and take the cover off.
- Connect the valve connector to the SHUT OFF connector from the controller.
- Install the cover and route the cable through the opening in the lower heating element cover.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 32. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.