Viessmann · Water heater troubleshooting

Install the G to NPT adaptors on the heating water connections

Vitocell 100-V CVWC

What is going on

Two 1 in. G to 1 in. NPT adaptors go on the heating system supply and return. Each one uses the gasket supplied with it.

Check in this order

  1. Place the gasket supplied with the adaptor on the adaptor.
  2. Thread the 1 in. G to 1 in. NPT adaptor into the heating supply or return connection. Do not overtighten, because this can damage the gasket.
  3. Use the wrench flats near the adaptor thread with the two-hand wrench method. Hold the adaptor with one wrench and tighten the fitting or pipe with the second.
  4. Repeat for the other adaptor.

Applies to: All Vitocell 100-V CVWC sizes

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocell 100-V CVWC installation manual, p. 15. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.