Navien · Water heater troubleshooting
External recirculation system layout
What is going on
An external loop lets hot water circulate continuously or on demand, which cuts the wait for hot water at fixtures. It usually uses a dedicated return line or a crossover valve, depending on plumbing and site.
Check in this order
- Insulate the loop well so the water heater does not run continuously.
- Expect the water heater to cycle more often once a recirculation loop is added.
- Follow the piping diagrams for top inlet and outlet, side inlet and outlet, or a return line with the optional side inlet.
- Use an on-demand button and a temperature sensor on the loop as shown in the diagrams.
- Add an expansion tank and connect the return water to the system per the diagram.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 37-40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.