Install the impressed current anode

Vitocell 100-V

What is going on

Field-installed anode with its electronic unit mounted on the tank jacketing. Power is connected only after the tank is filled.

Check in this order

  1. Isolate the system from the power supply and check that it is not live.
  2. Cut away the Styrofoam insulation behind the cable relief slot in the tank jacketing with a sharp knife.
  3. Mount the anode electronic unit to the jacketing, aligning the supplied screws with the pre-drilled holes.
  4. Route the anode cable through the cable relief slot and tuck it into the slot in the Styrofoam.
  5. Apply the supplied cable securing tape over the relief slot to hold the cable.
  6. Connect the female spade connector of the cable to the male spade connector of the anode.
  7. Place the hoop connector over the threaded stud of the sensor tie-down clamp and secure it with the supplied wing nut.
  8. After filling the DHW tank, connect the electronic unit to the power supply using its pre-wired convenience plug.

Applies to: Vitocell 100-V CVWC, all sizes

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocell 100-V CVWC installation, service and operating instructions, p. 16-17. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.