Navien · Water heater troubleshooting

Check compatibility before installing the HotButton Kit

NPN/NHW700

What is going on

The kit only works with A-type NPE-A (180A/210A/240A) or NPN/NHW700 water heaters. It does not work with S-type NPE units, with cascade (multi-unit) installs, or with the Navien H2 Air system. Recirculation pump sizing should allow 3–4 GPM through the heater.

Check in this order

  1. Confirm the water heater is an A-type NPE-A or an NPN/NHW700 unit.
  2. Confirm the install is not cascade (multi-unit) and not an H2 Air system.
  3. Size the recirculation pump for 3–4 GPM through the heater, and check the NPN/NHW700 installation manual for pressure loss.

Applies to: HotButton Kit on NPN/NHW700 water heaters

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien HotButton add-on controller installation manual, p. 1. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.