Navien · Water heater troubleshooting
Install the temperature sensor (optional)
What is going on
The sensor is optional on the non-pump model. Remove the default metal plate from SENSOR I before connecting a sensor.
Check in this order
- Remove the metal plate from the SENSOR I contacts on the circuit board.
- Connect the temperature sensor to the SENSOR I contacts.
- Insulate the sensor once it is installed.
- If the wire must be extended, use up to 30 m (100 ft) of 22 AWG wire.
Applies to: HotButton Kit temperature sensor input
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien HotButton add-on controller installation manual, p. 1–2. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.