Navien · Water heater troubleshooting

Install the H2Air controller in a water heater

H2AirNPE-ANPE-A2/S2NHW700-ANPN

What is going on

Mounting the H2Air add-on controller inside the water heater. The mounting method depends on the model (NPE-A, NPE-A2/S2, NHW700-A or NPN).

Check in this order

  1. Turn off the power to the water heater.
  2. Remove the front cover by loosening the four screws that hold it to the case.
  3. On NPE-A, remove the two screws holding the PCB tray, then pull the tray out of the unit.
  4. On NPE-A, hook the latch at the back of the H2Air case onto the front lip of the PCB tray, then pivot the controller down until the two rear latches snap onto the catch bars. Put the tray back and secure it with the two screws.
  5. On NPE-A2/S2, remove the existing HotButton controller and fit the H2Air in its place using the tabs on the housing.
  6. On NHW700-A, slide the back latch into the mounting hole on the front panel support bracket and slide the controller to lock it.
  7. On NPN, remove the screws holding the front panel to the bracket, hook the three back latches onto the bracket, and slide the controller down to lock it.
  8. Connect all cables to the H2Air (see the cable connections section, p. 18).
  9. Set the DIP switches for the installation setup (see the DIP switch table, p. 7).
  10. Put the PCB or front panel back into the water heater and secure it with the two screws.
  11. Close the front cover and fasten it with the four screws.

Applies to: NPE-A, NPE-A2/S2, NHW700-A, NPN water heaters with H2Air

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien H2Air installation manual, p. 11-14. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.