Choosing an operating mode
What is going on
Energy Saver (default) combines heat pump and electric heater. High Demand uses the electric heater more often for faster recovery. Heat Pump uses only the heat pump and is most efficient but slowest to recover. Electric uses only the upper and lower heaters, which do not run together, and is limited to 72 hours before returning to the previous mode. Vacation suspends tank heating for the set number of days while keeping freeze protection and anti-seize active. About 9 hours before the end, the unit returns to the previous mode and reheats to set temperature.
Check in this order
- Select the mode from the Menu button or the start-up wizard.
- For Vacation, set the number of days from 0 (Off) to 99 days.
- Set Electric mode only for short-term high demand, since it is the least efficient.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 User's Information Manual, p. 14. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.