Connecting a CTA-2045 demand response module

NWP500

What is going on

A CTA-2045 module (not supplied) connects to the designated port in the junction box on the top right side. Follow the supplier's instructions for startup. A thermostatic mixing valve meeting ASSE 1017 must be on the hot supply line in demand response installs.

Check in this order

  1. Turn the heater power OFF.
  2. Loosen the two screws on the top right junction box cover and remove the cover.
  3. Connect the CTA module to the CTA-2045 connection port.
  4. Install an ASSE 1017 thermostatic mixing valve on the hot water supply line per its instructions.

Applies to: NWP500-50, NWP500-65, NWP500-80

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.