Navien · Water heater troubleshooting
Connecting a CTA-2045 demand response module
What is going on
A CTA-2045 module (not supplied) connects to the designated port in the junction box on the top right side. Follow the supplier's instructions for startup. A thermostatic mixing valve meeting ASSE 1017 must be on the hot supply line in demand response installs.
Check in this order
- Turn the heater power OFF.
- Loosen the two screws on the top right junction box cover and remove the cover.
- Connect the CTA module to the CTA-2045 connection port.
- Install an ASSE 1017 thermostatic mixing valve on the hot water supply line per its instructions.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 30. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.