Top installation of the recirculation pump kit

ComfortCirc

What is going on

Connects the ComfortCirc recirculation pump to the water heater's RE-PUMP cable through the front panel. Steps 1 to 5 are on pages 14 and 15, which are not in this extract.

Check in this order

  1. Remove the two screws at the bottom of the front panel and take the panel off the water heater.
  2. Unplug the RE-PUMP cable from the controller.
  3. Connect the pump's communication cable to the RE-PUMP cable from the controller.
  4. Power the pump with the supplied power adapter.
  5. Make sure all cables are secured inside the front panel.
  6. Refit the front panel and fasten it with the two bottom screws.
  7. Check all piping connections for leaks before switching the water heater on.

Applies to: ComfortCirc recirculation pump, top-mount installation

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien ComfortCirc installation and operation manual, p. 16-17. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.