Navien · Water heater troubleshooting

Replace pipe O-rings

NWP500

What is going on

Use the matching O-ring from the Emergency Parts Kit. Improper or damaged O-rings cause leaks.

Likely causes

  • Damaged O-ring.
  • O-ring installed improperly.

Check in this order

  1. Top pipe upper location uses P22A O-ring.
  2. Top pipe lower location uses P26 O-ring.
  3. Side pipes use P24 O-ring.
  4. Check the O-ring is undamaged and seated correctly before restoring operation.

Applies to: NWP500 series

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 User's Information Manual, p. 30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.