Navien · Water heater troubleshooting
T&P valve leaking
What is going on
Water leaks from the T&P relief valve. The manual gives these corrective measures.
Likely causes
- Excess pressure on the cold water side
- Thermal expansion in a closed system
Check in this order
- Install a pressure reducing valve (PRV) on the cold water inlet, set to about 50–60 psi.
- Install an expansion tank rated for the system pressure.
- Adjust the tank temperature setting as needed.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 64. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.