Navien · Water heater troubleshooting
Drain and flush the tank
What is going on
Do this at least once a year to remove mineral deposits and reduce odor.
Check in this order
- Turn off power to the water heater.
- Open all faucets and connect a hose to the drain valve.
- Close the cold water supply valve and open the drain valve. Opening the T&P valve speeds draining.
- Close the drain valve and reopen the cold water supply valve.
- Keep faucets open while the tank fills.
- When the tank is full, close the faucets and restore power.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 66. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.