Navien · Water heater troubleshooting

Returning a unit to service after long inactivity

NWP500

What is going on

Steps to take when the unit will be idle for a long time and before it is restarted.

Check in this order

  1. Disconnect the power supply.
  2. Use Vacation mode to save energy if the unit stays powered (see section 5.5).
  3. Drain the pipes to prevent freezing.
  4. Before restarting, make sure the tank is full of water. Running it with an empty tank can overheat and damage the heating element.

Applies to: NWP500-50, NWP500-65, NWP500-80

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 66. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.