Navien · Water heater troubleshooting

Installing the drain pan

NWP500

What is going on

A drain pan is required under the heater to catch leaks, where local code requires it. Without one, leaks can damage nearby walls, floors and ceilings below.

Check in this order

  1. Use a drain pan at least 2 inches (50 mm) wider than the heater diameter.
  2. Keep the pan depth no more than 1-¾ inches.
  3. Set the pan on a level surface.
  4. Confirm the pan can support the full weight of the heater when filled with water.
  5. Run the pan's side outlet to a drainage system.

Applies to: NWP500-50, NWP500-65, NWP500-80

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 25. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.