Navien · Water heater troubleshooting

Test and maintain the T&P relief valve

NWP500

What is going on

Yearly test to keep the valve from sticking. The unit must always have a working T&P valve.

Check in this order

  1. Make sure no one is near the discharge, since water is very hot.
  2. Do not block the T&P discharge outlet.
  3. Open the T&P handle on the side of the unit and drain 1 to 2 gallons.
  4. If no water comes out, turn off the unit and call a licensed professional or Navien Technical Support.
  5. If the T&P valve leaks, install a PRV on the cold inlet set to 50 to 60 psi.
  6. If the T&P valve leaks, install an expansion tank with the correct pressure.
  7. Adjust the temperature setting as needed.

Applies to: NWP500 series

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 User's Information Manual, p. 27. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.