Navien · Water heater troubleshooting
Test and maintain the T&P relief valve
What is going on
Yearly test to keep the valve from sticking. The unit must always have a working T&P valve.
Check in this order
- Make sure no one is near the discharge, since water is very hot.
- Do not block the T&P discharge outlet.
- Open the T&P handle on the side of the unit and drain 1 to 2 gallons.
- If no water comes out, turn off the unit and call a licensed professional or Navien Technical Support.
- If the T&P valve leaks, install a PRV on the cold inlet set to 50 to 60 psi.
- If the T&P valve leaks, install an expansion tank with the correct pressure.
- Adjust the temperature setting as needed.
Applies to: NWP500 series
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 User's Information Manual, p. 27. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.