Navien · Water heater troubleshooting

Recirculation piping with NaviCirc, top inlet and outlet

NWP500

What is going on

Piping layout when the NaviCirc recirculation pump is used with top-mounted inlet and outlet connections. The return line can go to the optional side inlet, or the top inlet can be used for the return.

Check in this order

  1. Connect the city water supply to the water heater inlet.
  2. Connect the hot water outlet to the hot water line.
  3. Connect the return water line to the NaviCirc recirculation pump, using the top inlet or the optional side inlet for the return.
  4. Install the expansion tank in the supply side as shown in the diagram.
  5. Install the temperature sensor(s) as shown. The second sensor is only needed for Eco Recirculation mode.

Applies to: NWP500 with Navien NaviCirc recirculation pump, top inlet and outlet

More water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NWP500 installation manual, p. 40. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.