Installing the shut-off valve (optional, top mount)
What is going on
The optional shut-off valve stops the water supply when the leak detection system senses a leak. It is not installed by default. Mount it on the top near the outlet port, with the cable routed through the rubber packing.
Check in this order
- Turn the heater power OFF.
- Mount the shut-off valve on the top of the unit near the outlet port.
- Cut a slit in the rubber packing so the valve cable can pass through.
- Remove the rubber packing and pass the valve cable through it.
- Fit the packing into the top plate hole so it aligns.
- Remove the two screws at the bottom of the front panel and take the panel off.
- Disconnect the SHUT-OFF connector from the controller connector.
- Connect the valve connector to the SHUT OFF connector inside the cover.
- Route the cable through the opening in the lower heating element cover and reinstall the cover.
- Reinstall the front panel and fasten with the two bottom screws.
Applies to: NWP500-50, NWP500-65, NWP500-80
More water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NWP500 installation manual, p. 31-32. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.