Navien air conditioner error codes
145 codes (115 faults, 30 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| A251 | Alarm: PD high pressure protection | Medium |
| A252 | Alarm: PS low pressure protection | Medium |
| A253 | Alarm: TD discharge temperature protection | Medium |
| A254 | Alarm: CR compression ratio protection | Medium |
| A255 | Alarm: CUR overcurrent protection | Medium |
| A256 | Alarm: heatsink protection | Medium |
| A257 | Alarm: compressor temperature abnormal protection | Medium |
| A258 | Alarm: TS suction temperature protection | Medium |
| A259 | Alarm: superheat protection | Medium |
| A260 | Alarm: high pressure switch (HPS) protection | Medium |
| A851 | Inverter trip alarm: Communication error | Medium |
| A852 | Inverter trip alarm: Compressor current sensor error | Medium |
| A853 | Inverter trip alarm: DC link sensor error | Medium |
| A854 | Inverter trip alarm: PFCM current A error | Medium |
| A855 | Inverter trip alarm: PFCM current B error | Medium |
| A856 | Inverter trip alarm: Input voltage sensor error | Medium |
| A857 | Inverter trip alarm: Software compressor overcurrent | Medium |
| A858 | Inverter trip alarm: Overcurrent at compressor current limit | Medium |
| A859 | Inverter trip alarm: Overcurrent at ID current limit | Medium |
| A860 | Inverter trip alarm: Hardware compressor overcurrent | Medium |
| A861 | Inverter trip alarm: PFC overcurrent | Medium |
| A862 | Inverter trip alarm: Estimator fault | Medium |
| A863 | Inverter trip alarm: Compressor starting error | Medium |
| A864 | Inverter trip alarm: Wire miss error | Medium |
| A865 | Inverter trip alarm: Heatsink over temperature | Medium |
| A866 | Inverter trip alarm: DC under voltage | Medium |
| A867 | Inverter trip alarm: DC over voltage | Medium |
| A868 | Inverter trip alarm: AC under voltage | Medium |
| A869 | Inverter trip alarm: AC over voltage | Medium |
| A870 | Inverter trip alarm: PFC unbalanced current | Medium |
| A871 | Inverter trip alarm: Fan motor error (5 min) | Medium |
| A872 | Inverter trip alarm: Discharge FET error | Medium |
| A873 | Inverter trip alarm: Stator overheat (5 min) | Medium |
| A874 | Inverter trip alarm: PBA (power board) over temperature | Medium |
| d0 | Oil return cycle | Normal status |
| E201 | High pressure (PD) protection error | High |
| E202 | Low pressure (PS) protection error | High |
| E203 | Compressor discharge temperature (TD) protection error | High |
| E204 | Compression ratio (CR) protection error | High |
| E205 | Overcurrent (CUR) protection error | High |
| E206 | Heatsink protection error | High |
| E207 | Compressor temperature abnormal error | High |
| E208 | Compressor suction temperature (TS) protection error | High |
| E209 | Superheat protection error | High |
| E210 | High pressure switch (HPS) protection error | High |
| E501 | Outdoor temperature sensor (Ta) open/short | Medium |
| E505 | Compressor discharge temperature sensor (TD) open/short | Medium |
| E506 | Compressor suction temperature sensor (TS) open/short | Medium |
| E507 | Condenser outlet temperature sensor (Tcond) open/short | Medium |
| E561 | Discharge pressure sensor (PD) open/short | Medium |
| E562 | Suction pressure sensor (PS) open/short | Medium |
| E702 | Outdoor unit to inverter driver communication failure | High |
| E801 | Inverter trip: Communication error | High |
| E802 | Inverter trip: Compressor current sensor error | High |
| E803 | Inverter trip: DC link sensor error | High |
| E804 | Inverter trip: PFCM current A error | High |
| E805 | Inverter trip: PFCM current B error | High |
| E806 | Inverter trip: Input voltage sensor error | High |
| E807 | Inverter trip: Software compressor overcurrent | High |
| E808 | Inverter trip: Overcurrent at compressor current limit | High |
| E809 | Inverter trip: Overcurrent at ID current limit | High |
| E810 | Inverter trip: Hardware compressor overcurrent | High |
| E811 | Inverter trip: PFC overcurrent | High |
| E812 | Inverter trip: Estimator fault | High |
| E813 | Inverter trip: Compressor starting error | High |
| E814 | Inverter trip: Wire miss error | High |
| E815 | Inverter trip: Heatsink over temperature | High |
| E816 | Inverter trip: DC under voltage | High |
| E817 | Inverter trip: DC over voltage | High |
| E818 | Inverter trip: AC under voltage | High |
| E819 | Inverter trip: AC over voltage | High |
| E820 | Inverter trip: PFC unbalanced current | High |
| E821 | Inverter trip: Fan motor error (5 min) | High |
| E822 | Inverter trip: Discharge FET error | High |
| E823 | Inverter trip: Stator overheat (5 min) | High |
| E824 | Inverter trip: PBA (power board) over temperature | High |
| E999 | Error of unknown cause | High |
| F0 | Communication fault (outdoor unit) | High |
| F1 | Low pressure switch fault | High |
| F4 | T4 outdoor ambient sensor fault | Medium |
| F5 | T5 compressor discharge sensor fault | Medium |
| F6 | T3 condenser coil sensor fault | Medium |
| F7 | T7 sensor fault | Medium |
| F8 | T7 sensor: condensate risk on the cooling plate | Medium |
| F9 | Line voltage too low or too high | High |
| H0 | Communication fault between chips on the outdoor PCB | High |
| H1 | Lockout: outdoor coil too hot (P5 repeated) | High |
| H2 | Lockout: high pressure switch (P1 repeated) | High |
| H3 | High pressure abnormal (sensor over 3.6 MPa) - heating mode | High |
| H4 | Lockout: drive module overheating (P8 repeated) | High |
| H5 | Lockout: low pressure (P2 repeated) | High |
| H6 | Lockout: high discharge temperature (P4 repeated) | High |
| H7 | Lockout: low discharge superheat (PC repeated) | High |
| H8 | Lockout: T3 probe off the pipe (FE repeated) | High |
| L0 | DC bus voltage too low | High |
| L1 | DC bus voltage too high | High |
| P1 | High pressure switch opened | High |
| P2 | Low pressure protection | High |
| P3 | Compressor drive overcurrent | High |
| P4 | Discharge temperature too high | High |
| P5 | Condenser coil (T3) temperature too high - cooling | High |
| P6 | Compressor drive (IPM) module protection | Critical |
| P8 | Drive module (IPM) overheating | High |
| P9 | Outdoor fan motor fault | High |
| R101 | Condenser heat exchange abnormal alarm | Menu / mode display |
| R301 | Supply solenoid valve stuck alarm | Menu / mode display |
| R302 | Drain solenoid valve stuck alarm | Menu / mode display |
| R303 | Water supply abnormality alarm | Menu / mode display |
| R563 | Water pressure sensor open/short alarm | Menu / mode display |
| R601 | EEPROM alarm | Menu / mode display |
| R602 | NOR flash alarm | Menu / mode display |
| R881 | Inverter minor: IPM temperature sensor error | Menu / mode display |
| R882 | Inverter minor: PFCM temperature sensor error | Menu / mode display |
| R883 | Inverter minor: ID current limit minor | Menu / mode display |
| R884 | Inverter minor: Compressor current limit minor | Menu / mode display |
| R885 | Inverter minor: AC over voltage | Menu / mode display |
| R886 | Inverter minor: PFC overcurrent | Menu / mode display |
| R887 | Inverter minor: Input current limit | Menu / mode display |
| ATL | Outdoor temperature outside operating range | Medium |
| FA | Outdoor board memory (EEPROM) fault | High |
| FB | Drive chip memory (EEPROM) fault | High |
| FC | Drive module temperature sensor fault | High |
| FD | Pressure sensor not detected | High |
| FE | T3 or T5 probe out of position | Medium |
| FF | High pressure switch reads open all the time | High |
| HC | Lockout: discharge probe off the pipe (FE repeated) | High |
| HE | Repeated condensate-risk faults (F8) | Medium |
| HI | Charging mode: outdoor air too hot | Normal status |
| LA | Compressor speed held back by voltage | Normal status |
| LB | Compressor speed held back by high pressure | Normal status |
| LC | Compressor speed held back by condenser temperature | Normal status |
| LD | Compressor speed held back by discharge temperature | Normal status |
| LE | Compressor speed held back by drive module temperature | Normal status |
| LF | Compressor speed held back by current | Normal status |
| LO | Charging mode: outdoor air too cold | Normal status |
| PC | Low discharge superheat (liquid floodback risk) | High |
| PC, H7 | Moisture exposure error (overheat, T5-T3 under 9°F / 5°C) | High |
| PD | High pressure too high | High |
| PRH | Crankcase heater warm-up, no start yet | Normal status |
| ST.10 | Standby | Normal status |
| ST.20 | Initial startup | Normal status |
| ST.30 | Normal operation | Normal status |
| ST.40 | Post-stop delay | Normal status |
| TH | Charging mode: no thermostat call | Normal status |
| dC | Forced cooling | Normal status |
Models covered
NAA17V36NAA17V60NAE28V3622A1NAE28V6022A1
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.