Navien · Air conditioner
E803 Inverter trip: DC link sensor error
What the control is telling you
Inverter trip error shown after alarm 853 occurred four times. Manual reset needed (display shows 803).
Applies to: NAE28V3622A1, NAE28V6022A1
Test and repair steps
- Turn off power at the disconnect before opening the unit.
- Check the sensor connector and replace the sensor if needed.
- Check the input power.
- Update the firmware or replace the inverter.
- It can be a one-time glitch. Reboot and check again.
Models that show this code
2 models in Navien NAE
Other codes on the same units
- E562 Suction pressure sensor (PS) open/short
- E702 Outdoor unit to inverter driver communication failure
- E801 Inverter trip: Communication error
- E802 Inverter trip: Compressor current sensor error
- E804 Inverter trip: PFCM current A error
- E805 Inverter trip: PFCM current B error
- E806 Inverter trip: Input voltage sensor error
- E807 Inverter trip: Software compressor overcurrent
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NAE I&O manual (07/2026), 7.1 Error table and 7.2.20, p.58. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.