Navien · Air conditioner
E804 Inverter trip: PFCM current A error
What the control is telling you
Inverter trip error shown after alarm 854 occurred four times. Manual reset needed (display shows 804).
Applies to: NAE28V3622A1, NAE28V6022A1
Likely causes
- Sensor broken or loose
- Unstable input power, DC link voltage too high or low
- Wrong sensor reading from firmware or board fault
Test and repair steps
- Turn off power at the disconnect before opening the unit.
- Check power to the compressor.
- Check the sensor connector and measure PFCM input and output current.
- Check for overheating.
- It can be temporary electrical noise. Reboot and check again.
Models that show this code
2 models in Navien NAE
Other codes on the same units
- E702 Outdoor unit to inverter driver communication failure
- E801 Inverter trip: Communication error
- E802 Inverter trip: Compressor current sensor error
- E803 Inverter trip: DC link sensor error
- E805 Inverter trip: PFCM current B error
- E806 Inverter trip: Input voltage sensor error
- E807 Inverter trip: Software compressor overcurrent
- E808 Inverter trip: Overcurrent at compressor current limit
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NAE I&O manual (07/2026), 7.1 Error table and 7.2.21, p.58. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.