Navien · Air conditioner

E823 Inverter trip: Stator overheat (5 min)

High severity Navien NAE

What the control is telling you

Inverter trip error shown after alarm 873 occurred four times. Manual reset needed (display shows 823).

Applies to: NAE28V3622A1, NAE28V6022A1

Likely causes

  • Compressor failure
  • Inverter damaged

Test and repair steps

  1. Turn off power at the disconnect before opening the unit.
  2. Check compressor winding resistance, and check that the compressor leads are on U, V, W correctly.
  3. Replace the inverter.

Models that show this code

2 models in Navien NAE

NAE28V3622A1NAE28V6022A1

Other codes on the same units

  • E817 Inverter trip: DC over voltage
  • E818 Inverter trip: AC under voltage
  • E819 Inverter trip: AC over voltage
  • E820 Inverter trip: PFC unbalanced current
  • E821 Inverter trip: Fan motor error (5 min)
  • E822 Inverter trip: Discharge FET error
  • E824 Inverter trip: PBA (power board) over temperature
  • E999 Error of unknown cause

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NAE I&O manual (07/2026), 7.1 Error table and 7.2.40, p.62. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.