Navien · Air conditioner

R601 EEPROM alarm

Menu / mode display Navien NAE

What the display is showing

Minor code. Manual reset.

Applies to: NAE28V3622A1, NAE28V6022A1

Good to know

  • Power instability or noise
  • Mainboard damage

What to do

  1. Reboot and check again, it can be temporary.
  2. Replace the mainboard if it returns.

Models that show this code

2 models in Navien NAE

NAE28V3622A1NAE28V6022A1

Other codes on the same units

  • R301 Supply solenoid valve stuck alarm
  • R302 Drain solenoid valve stuck alarm
  • R303 Water supply abnormality alarm
  • R563 Water pressure sensor open/short alarm
  • R602 NOR flash alarm
  • R881 Inverter minor: IPM temperature sensor error
  • R882 Inverter minor: PFCM temperature sensor error
  • R883 Inverter minor: ID current limit minor

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NAE I&O manual (07/2026), 7.3 and 7.3.6, p.64. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.