R303 Water supply abnormality alarm

Menu / mode display Navien NAE

What the display is showing

Minor code (water supply). Resets by itself or by hand.

Applies to: NAE28V3622A1, NAE28V6022A1

Good to know

  • Water locked out for freeze protection and not turned on in season
  • Customer shut the water off on purpose
  • Water cut off
  • Solenoid valve stuck off
  • No power to the valve from a short, missing or bad terminal block
  • Valve stuck on after drying operation
  • Small debris in the diaphragm causing a slow leak at the drain valve
  • Large debris in the diaphragm causing a large leak at the drain valve

What to do

  1. Test the supply solenoid valve on and off.
  2. Test the drain solenoid valve on and off.
  3. Check the main water line.

Models that show this code

2 models in Navien NAE

NAE28V3622A1NAE28V6022A1

Other codes on the same units

  • R101 Condenser heat exchange abnormal alarm
  • R301 Supply solenoid valve stuck alarm
  • R302 Drain solenoid valve stuck alarm
  • R563 Water pressure sensor open/short alarm
  • R601 EEPROM alarm
  • R602 NOR flash alarm
  • R881 Inverter minor: IPM temperature sensor error
  • R882 Inverter minor: PFCM temperature sensor error

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NAE I&O manual (07/2026), 7.3 and 7.3.4, p.64. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.