Navien · Air conditioner

E811 Inverter trip: PFC overcurrent

High severity Navien NAE

What the control is telling you

Inverter trip error shown after alarm 861 occurred four times. Manual reset needed (display shows 811).

Applies to: NAE28V3622A1, NAE28V6022A1

Likely causes

  • Unstable or very high voltage
  • Leakage current from dust or moisture
  • Inverter damage

Test and repair steps

  1. Turn off power at the disconnect before opening the unit.
  2. It may be temporary. Reboot and check.
  3. Check the input power.
  4. Replace the inverter.

Models that show this code

2 models in Navien NAE

NAE28V3622A1NAE28V6022A1

Other codes on the same units

  • E807 Inverter trip: Software compressor overcurrent
  • E808 Inverter trip: Overcurrent at compressor current limit
  • E809 Inverter trip: Overcurrent at ID current limit
  • E810 Inverter trip: Hardware compressor overcurrent
  • E812 Inverter trip: Estimator fault
  • E813 Inverter trip: Compressor starting error
  • E814 Inverter trip: Wire miss error
  • E815 Inverter trip: Heatsink over temperature

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NAE I&O manual (07/2026), 7.1 Error table and 7.2.28, p.60. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.