Navien · Air conditioner

E814 Inverter trip: Wire miss error

High severity Navien NAE

What the control is telling you

Inverter trip error shown after alarm 864 occurred four times. Manual reset needed (display shows 814).

Applies to: NAE28V3622A1, NAE28V6022A1

Likely causes

  • Poor connector contact
  • A wire left unconnected at installation

Test and repair steps

  1. Turn off power at the disconnect before opening the unit.
  2. Check wiring between the compressor, inverter and control board.
  3. Check connectors for damage.
  4. Confirm all wires are connected.

Models that show this code

2 models in Navien NAE

NAE28V3622A1NAE28V6022A1

Other codes on the same units

  • E810 Inverter trip: Hardware compressor overcurrent
  • E811 Inverter trip: PFC overcurrent
  • E812 Inverter trip: Estimator fault
  • E813 Inverter trip: Compressor starting error
  • E815 Inverter trip: Heatsink over temperature
  • E816 Inverter trip: DC under voltage
  • E817 Inverter trip: DC over voltage
  • E818 Inverter trip: AC under voltage

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NAE I&O manual (07/2026), 7.1 Error table and 7.2.31, p.60. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.